Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameHILTON HOTEL
Address8629 J M KEYNES DR
 
City/State/ZIP
CHARLOTTE NC 28262
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 11/16/2017
Final Score @ Grade
20
General Comments15) Outer rope on ring buoy starting to fray. Recommend replacing. 21) Pool open at night. Underwater light on a photosensor. Ensure underwater light turns on at night. 22) 911 had difficulty hearing me. Recommend checking the phone and phone lines. Immediate suspension issued. 6) Contact Will Harrison (704-507-6824) for reinspection when issues are corrected.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Main drains not being checked every day. Cyanuric Acid at 100ppm for the summer. Check daily Cl, pH, main drains and at least weekly total alkalinity and cyanuric acid. Maintain Cyanuric Acid at no more than 100ppm.
6 6 Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ No No No Screw on one of the main drain covers rusted. Install with stainless steel screws per manufacturer's instructions. - Immediate suspension item.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No One ladder loose. Maintain secure and in good condition.
18 4 Premises: lifeguards present or warning signs posted No No No Lettering on "WARNING NO LIFEGUARD ON DUTY SIGNAGE TOO SMALL". Provide in at least 4 inch lettering "WARNING-NO LIFEGUARD ON DUTY". - Intent to suspend item.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter stuck. Repair or replace.