Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameBERKSHIRE DILWORTH
Address1351 E MOREHEAD ST
 
City/State/ZIP
CHARLOTTE NC 28204
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 3/5/2026
Final Score @ Grade
14
General CommentsInspection completed with Gilmer Fernandez present. Intent to suspend permit issued for non operational flow meter. Correct within 30 days or permit may be suspended. Lawson Main Drains expire 8/1/2026. The Paddock Main Drains will have to be evaluated after the 10 year date(8/1/2026) for any damage, and the evaluation recorded. This must then be done once a year thereafter and recorded. The screws must be replaced with stainless steel screws every 7 years and this must be recorded. Permit Restrictions: Lock on filter required. Flow meter shall not exceed 450 GPM due to filter size restriction. Lock valve on pump required at all times for backwash and filtration. Doors to deck must remain permanently locked. Note- some depth markers at sun shelf are peeling/beginning to peel. Replace as needed.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No .2535(1) Maintain pH at 7.2 to 7.8. Observed initial pH reading at 6.8. CDI- adjusted to 7.2.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Observed ladder with missing rubber end cap.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No .2518(g) Keep flow meter operational. Observed flow meter non operational. Intent to suspend permit issued as there is a permit condition/restriction with flow on this pool. Correct within 30 days.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No .2526(j) Provide soap and soap dispenser, no glass, at each sink. Observed no hand soap in mens restroom nearest pool.