21
|
4
|
Premises: pool and deck lighting provided at pools that operate at night |
No |
No
|
No |
Posted pool hours are 6AM - 10PM. Insufficient deck lighting for operation during non-daylight hours. Change pool hours to only operate during daylight hours or provide at least 10 foot candles of lighting in the pool and at all parts of the pool deck. - Intent to suspend item. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
No phone number posted at emergency phone. Post phone number for emergency phone. Corrected by operator. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Current filter setup is to have the filter partially bypassed. Filter should not be operating on a partial bypass. Will check the construction files and follow up on my return visit. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Chemicals stored in storage closet in men's restroom. Store chemicals in chemical storage room only. Corrected by operator. |