Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameHOME 2 SUITES BY HILTON CLT AIRPORT
Address4240 SCOTT FUTRELL DR
 
City/State/ZIP
CHARLOTTE NC 28208
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 2/21/2023
Final Score @ Grade
26
General CommentsInspection conducted with Angel Rivera-Delcon. Intent to suspend issued due to the following items: Far gate and main hotel entry door do not latch closed, missing vacuum port cover, and missing/incomplete record keeping. Repair door and gate to fully self-close and latch, replace missing vacuum port cover, and maintain records as required. EHS will return within 30 days to evaluate. If all items are not in compliance, permit will be suspended. Call Hope McIntosh at 980-229-7549 with questions. Night swimming not permitted.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No .2535(1) Maintain pH at 7.2 to 7.8. Pool water pH 8.0. Corrected to 7.4 during inspection.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Observed no records maintained during months of Dec and Jan. Operator indicated pool was closed but not noted on any record. Records resume Feb ‘23 missing weekend ph and cl readings. No main drain checks documented. Intent to suspend items
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed one of the 2 buoys present with rope length exceeding 20’. Shortened to 19’ during inspection.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2537(b) All gates and doors shall be self-closing, self-latching. Main door entry from hotel does not latch when closed and does not have audible alarm. Card reader/lock is not working and operator noted they leave the door unlocked until 9pm. Gate at far end of pool not latching closed every time. Some breeze present but not sufficient to prevent gate from operating normally, Operator noted that spring cannot be tensioned any tighter. Repair to ensure full closure and latch every time. Intent to suspend items
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No .2518(f) Provide a vacuum cap or self-closing cap for pools built after May 1, 2010. No cap on vacuum line port on pool wall. Pool built 2016. Locking cover missing. Replace. Intent to suspend item
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor. Bag of dry chemicals stored directly on chemical room floor.