NameHOME 2 SUITES BY HILTON CLT AIRPORT
Address4240 SCOTT FUTRELL DR
 
City/State/ZIP
CHARLOTTE NC 28208
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 7/12/2022
Final Score @ Grade
0
General CommentsInspection completed with Rodney Searcy present. In-field plan review completed. 1. Flow = 60 GPM 2. Pump verified to be PENTAIR INTELLIFLO VSF 011056 3. Main drain pipe diameter = 2.5 inches; skimmer = 2.5 inches; return = 2 inches 4. (2) Aquastar 914xxx drain covers installed and verified 5. (2) waterway 640-9210 equalizer line covers installed and verified 6. PENTAIR TR 160 Filter verified and installed 7. Observed 4 total returns on pool wall 8. 2 skimmers verified today

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments