Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameHOME 2 SUITES BY HILTON CLT AIRPORT
Address4240 SCOTT FUTRELL DR
 
City/State/ZIP
CHARLOTTE NC 28208
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 11/7/2018
Final Score @ Grade
14
General Comments5) Salt pool. Currently no cyanuric acid in the swimming pool. Recommend having some cyanuric acid in the pool to stabilize the chlorine, especially in the summer when water temperature is higher and the pool is in the sun more. Operator will be using stabilized chlorine when water gets too cold to use salt generator. 5) A few days in a row of pH 7.9 with no corrective actions taken. Maintain proper water chemistry and document pool maintenance activities such as chemicals added, backwashing, etc.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No .2535(1) pH 8.2. Maintain between 7.2 and 7.8. Corrected to 7.3.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No .2535(11) Operator on vacation for a week, no records for November. No Cyanuric Acid records. Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, and pool water maintenance. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Maintain cyanuric acid at no more than 100ppm. Operator tested chemicals.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No .2518(f) Vacuum on in pump room. Vacuum cap not closed in pool. Provide a vacuum cap or self-closing cap for pools built after May 1, 2010. Corrected by operator.