3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
.2535(1) Maintain pH at 7.2 to 7.8. Observed pH to be 8.0 during the inspection. Corrected to 7.6 -CDI |
|
12
|
4
|
Pool maintenance: inlets and other fittings in place and in good repair |
No |
No
|
No |
.2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. Observed vacuum line cap to have become damaged and no longer latches. This pool requires a cap that is self-closing and self-latching such that a tool is required to open it. Provide a proper cap for the vacuum line. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
.2537(2) Decks shall be kept in good repair. Observed an area of deck where polymeric sand has settled and resulted in an off-set greater than 1/2 inch from the grade of the deck. It has become a trip hazard. Repair this area (paver stone area next to the pool edge) it a way that maintains the impervious surface of the deck. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone.
Observed incorrect number posted on the phone sign. Correct number (980-299-5332) was determined and posted. -CDI |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
.2533(e) Provide continuous forced ventilation or cross ventilation in room. Observed chemical storage room to have ventilation fan not working. Ensure proper ventilation for staff and resident safety. |