Name1010 DILWORTH
Address1010 KENILWORTH AVE
 
City/State/ZIP
CHARLOTTE NC 28204
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 3/20/2025
Final Score @ Grade
22
General CommentsMain drain covers will expire 5/11/2026 Equalizer line covers will expire 3/22/2026 They must be replaced and the PDSC paperwork submitted and approved by the Health Department prior to those dates. Observed ring buoy to be degrading in condition due to weather. Replace or have a spare properly approved ring buoy available prior to the buoy degrading to the point where it becomes a violation item. Intent to Suspend issued, Deadline is 4/19/2025. Failure to correct the required items may result in closure of the pool.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No .2535(1) Maintain pH at 7.2 to 7.8. Observed pH to be 8.0 during the inspection. Corrected to 7.6 -CDI
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. Observed vacuum line cap to have become damaged and no longer latches. This pool requires a cap that is self-closing and self-latching such that a tool is required to open it. Provide a proper cap for the vacuum line.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No .2537(2) Decks shall be kept in good repair. Observed an area of deck where polymeric sand has settled and resulted in an off-set greater than 1/2 inch from the grade of the deck. It has become a trip hazard. Repair this area (paver stone area next to the pool edge) it a way that maintains the impervious surface of the deck.
22 6 Premises: emergency telephone provided No No No .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Observed incorrect number posted on the phone sign. Correct number (980-299-5332) was determined and posted. -CDI
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2533(e) Provide continuous forced ventilation or cross ventilation in room. Observed chemical storage room to have ventilation fan not working. Ensure proper ventilation for staff and resident safety.