Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
Name1010 DILWORTH
Address1010 KENILWORTH AVE
 
City/State/ZIP
CHARLOTTE NC 28204
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 10/15/2020
Final Score @ Grade
34
General Comments6 - General Comment - Equalizer line covers are expiring in May 2021. New equalizers must be installed prior to 2021 operating permit issuance with new Pool Drain Suction Compliance form submitted and approved. Immediate Suspension issued for pool chlorine and USCG approved ring buoy with 45 ft. rope. Once the chlorine and ring buoy/rope are corrected, please call Katie at 704-309-5494 to schedule a return visit to reopen the pool. The pool must remain closed until a return visit has been made. Patrick present during the inspeciton. No signature due to covid restrictions. Emailed to maintenance and manager emails provided. Note: Extra cartridge filters present; however, operator stated they ordered new instead of recleaning. Either provide cleaned cartridges or new filter cartridges. Pool is not approved for night swimming.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
2 6 Water quality: disinfectant residual provided by No No No Pool chlorine at 0.2 ppm. Chlorinator turned up during inspection with no increase in chlorine. Maintain chlorine at least 1.0 ppm through chlorinator. Immediate Suspension issued.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Records not maintained for October. Maintain daily record keeping for chlorine, pH and main drain/equalizer line cover checks. Maintain weekly cyanuric acid and total alkalinity checks. Cyanuric acid >100 ppm. Maintain cyanuric acid at 100 ppm or below.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Some algea build-up on walls. Continue to monitor and treat as needed.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Skimmers with leaf build-up. Keep skimmers free of debris. Corrected during inspection.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Ring buoy grab rope beginning to degrade and ring buoy rope with damage. Replace with USCG approved ring buoy and 45 ft. rope. Immediate Suspension issued.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Three windows missing limiters located on right side of mailbox entry from inside pool enclosure. Windows shall be limited at 4" or less. Door from amenity space with latching mechanism beginning to pull out. Repair to door. Note: Double doors - one door permanently affixed due to not self-closing, self-latching.
23 4 Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 No No No Facility using salt as primary. Pool is not approved for salt as primary chlorination. Stick feeder must be utilized for chlorination. Hayward Saline c6.0 installed which produces 5 lbs/day of chlorine. Pool requires, based on pool volume of 24,066, at least 7.72 lbs per day of chlorine.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Chemicals stored so that chemical storage room not clearly accessible. Rearrange chemicals so that chemical storage room remains accessible.