9
|
4
|
Pool maintenance: depth markings and no diving markers or signs visible and properly located |
No |
No
|
No |
Depth marker and no diving markers wearing off in multiple locations.
.2523(c) Depth markers shall be 4 inches in height and of a contrasting color with the background, clearly visible.
.2523(d) No Diving markers shall be written in four inch letters or international 6"x6" no diving in red and black on a white background.
Intent to Suspend items. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Observed greater than 10 ft between handrails at sun shelf and steps. Pool built prior to 2010. .2521(b) Steps greater than 20 ft in width shall have one handrail every 10 ft. |
|
12
|
4
|
Pool maintenance: inlets and other fittings in place and in good repair |
No |
No
|
No |
One fitting missing from pool wall. Replace pool return fitting.2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair.
Intent to Suspend item. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Ring buoy rope >23 ft. Corrected during inspection. .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Observed offsets presenting trip hazards at pavers on either side of swimming pool. Eliminate offsets. .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile.
Intent to Suspend item. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
Emeregency phone not operable. Would not connect to 911. Could not verify address and phone number. Immediate Suspension issued.
.2530(a) Emergency phone shall remain operable.
.2530(a) Pool telephone shall be capable of directly dialing 911 or another emergency notification system. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Flow meter stuck. .2518(g) Keep flow meter operational.
Intent to Suspend item. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Floor drain covered in pump room. .2533(d) Provide drain in pump room floor. |
|
30
|
2
|
Dressing and sanitary facilities: approved water source, no cross connections |
No |
No
|
No |
Hose bib in pump room and in restrooms without backflow preventor. .2512(b) Water introduced into the pool, either directly or by the circulation system, shall be supplied through an air gap, anti-siphon vacuum breaker, or backflow preventer. |