Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Daily and weekly required tests must be done with liquid test kit. Strips are in use currently. The strips cannot be used for the recorded daily and weekly tests. Only for extra, unofficical spot checks. |
|
6
|
6
|
Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ |
No |
No
|
No |
Observed PDSC data on file with Health Department not to match pump for fountain feature in the system. The fountain pulls off of the main drain system. The PDSC data states the fountain pump is a Whisperflow WFE-12 3HP pump. The pump observed is an Intelliflow Varible speed 3HP pump. The information sent to the Health Department and the equipment in use must match. Pool is closed untill updated PDSC form is sent to Katie Wilson for approval. I.S. Issued. . |
|
9
|
4
|
Pool maintenance: depth markings and no diving markers or signs visible and properly located |
No |
No
|
No |
Observed some of the painted "NO DIVING" symbols to have become faded and worn. Re-paint the "NO DIVING" and depth marker sysmbols that have become worn/faded to return them to their previous state. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Ring Buoy throw rope is to be 23 feet long at this pool. Rope was observed to be 24 feet long. Rope was shorted to 23 feet. -C.D.I. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Observed gate not fully self-closing. Staff member corrected the gate. C.D.I. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Observed deck chairs too close to the water. Pool side furniture must be at least 6 feet back from the water edge of the pool. Furniture was moved. |
|
18
|
4
|
Premises: lifeguards present or warning signs posted |
No |
No
|
No |
Observed "WARNING NO LIFEGUARD ON DUTY" sign to be in 2 inch high letters. The law requires the letters of the sign to all be 4 inches high. A sign with "WARNING NO LIFEGUARD ON DUTY" all in 4 inch high letters must be provided. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Observed flow meter stuck. Repair it. |