Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameGUATE LINDA
Address6016 THE PLAZA
 
City/State/ZIP
CHARLOTTE NC 28215
Premise Type1 - Restaurant
CountyMecklenburg
Inspection Date 8/21/2017
Final Score @ Grade
92.50 A
General Comments

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
1 2 PIC present, Demonstration - Certification by accredited program, and performs duties No No No 2-102.12 PIC shall demonstrate knowledge by being a certified food protection manager. PIC is not food safety certified.
4 1 Proper eating, tasting, drinking, or tobacco use Yes No No 2-401.11 Cover and store employee drinks to prevent contamination of food or utensils. observed several employee beverages stored on food prep tables, one beverage uncovered. CDI by discard.
13 1.50 Food separated and protected Yes No No 3-302.11(A)(4) Protect food in storage using covered containers, intact wrappings, or packaging. observed several pans of food uncovered in walk-in cooler. CDI - food items were voluntarily discarded due to temperature violation. 3-304.11 Food shall only contact surfaces of properly cleaned and sanitized equipment and utensils. -P observed beverages stored in ice inside ice machine. CDI by removing beverages, draining and cleaning ice bin of ice machine.
20 3 Proper cold holding temperatures Yes Yes Yes 3-501.16(A)(2) Maintain TCS foods in cold holding at 45F or less. -P observed 2 chicken dishes, 1 beef dish, 1 stock pot of chicken stock stored in walk-in cooler > 45F. PIC stated that food items had been in cooler since yesterday. CDI by voluntary discard. **Ambient air temperature observed 57F in walk-in cooler. PIC will voluntarily close until cooler is repaired. PIC will contact REHS when cooler is repaired. Verification required.
45 0 Equipment, food and non-food-contact surfaces approved; cleanable, properly designed, constructed and used No No Yes 4-501.11 Maintain equipment in good repair. observed ambient air temperature of 57F inside walk-in cooler.
54 0 Meets ventilation and lighting requirements; designated areas used No No No 6-303.11 Intensity-Lighting - lighting in dry storage room is insufficient due to items stocked in room blocking light.