2
|
1
|
Certified Food Protection Manager |
No |
Yes
|
No |
2-102.12 (A) PIC shall demonstrate knowledge by being a certified food protection manager. Observed no CFPM on site during inspection. -REPEAT VIOLATION-
For more information on becoming a certified food protection manager please visit: https://health.mecknc.gov/envhealth/food-and-facilities-sanitation |
|
16
|
1.50
|
Food-contact surfaces: cleaned & sanitized |
No |
No
|
No |
4-501.114 Maintain sanitizer at correct concentrations when being used to sanitize. -P Observed in use dish machine at zero ppm chlorine solution. After running dish machine 3 times there still was zero ppm solution at dish machine. PIC contacted technician to fix machine. VR-A verification visit will be conducted within 3 days for corrected sanitizer solution at dish machine. REHS instructed PIC to only use 3 compartment sink until dish machine has been serviced.
For more information please visit: https://health.mecknc.gov/envhealth/food-and-facilities-sanitation or view our training videos at the following weblinks: Sanitizing Solutions - https://youtu.be/ykP2mr9CtRg and How to Test Sanitizer https://youtu.be/y0SjmnabFaY |
|
49
|
0.50
|
Non-food contact surfaces clean |
No |
No
|
No |
4-601.11(C ) Keep non food contact surfaces of equipment clean to avoid build up of dust, food residue or debris.4-602.13 Non food contact surfaces of equipment shall be cleaned frequently to preclude accumulation of soil residues. Observed surface of reach in freezer with dried purple spillage and in need of cleaning. Also observed cleaning needed on dry storage rack shelving with dust and debris on racks. |
|
55
|
0
|
Physical facilities installed, maintained & clean |
No |
No
|
No |
6-501.12 Floors, walls, ceilings including the attachments such as soap, towel dispensers; light fixtures; and heat/ac vent covers shall be clean. Caution should be used to minimize food exposure. Observed cleaning needed on ceiling vents at clean dish area with accumulation of dust. |
|
56
|
0
|
Meets ventilation & lighting requirements; designated areas used |
Yes |
No
|
No |
6-403.11 (A)Areas designated for employees to eat and drink, shall be located so that food, equipment, linens, single service/use items are protected from contamination. Observed have empty bottle of water stored at clean dish rack with pots stored on them. CDI- PIC removed water bottle. |