Inspection Date 3/25/2026
Final Score @ Grade
12
General CommentsPOOL IS NOT APPROVED FOR NIGHT SWIMMING. PERMIT RESTRICTIONS: WINDOWS MUST REMAIN WITH LIMITERS AT 4” OR LESS. MAIN DRAINS EXPIRE 5/29/2030

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Provide USCG approved ring buoy. A rescue tube with lifeguard may be substituted for ring buoy. Observed ring buoy to be in disrepair. New approved ring buoy was provided and attached with proper length throw rope (37 feet, 6 inches is the required exact length for this pool). -CDI violation was corrected.
23 4 Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 No No No .2535 Automatic acid feeder shall be automatically prevented from operating when the circulation pump is not in operation. Observed auto shut off not to be able to be observed to function. The shut off must work and be demonstrated to function. 30 day intent to suspend issued. Deadline is April 24th 2026. Failure to correct this by the deadline may result in closure of the pool.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2533(d) Pump room floor shall be kept dry and free of standing water. Observed some water from a leak in the pump room piping. Fix the leak.