5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
.2535 (11) The pool operator shall inspect the pool at least daily and maintain written records.
Observed facility not checking main drains and temperature of heated pool and no records of weekly check of TA or CA for april and more than a week pass before checking on previous months. Intent to suspend. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
.2528(a) Ground level windows shall not open greater than 4" on to pool deck or child protected by audible alarm.
Observed stoppers on two windos that allow windows to open more than 4". Intent to suspend issued.
.2528(a) Maintain 45" between bottom horizontal and next horizontal on fence and/or gate (post-May 2010).
Observed fences near the grill area that has a 41" height between horizontals. Facility can repair issue by adding pexiglass or mesh to the fence or adding additional height to fences. Intent to suspend issued.
Also observed patio furniture on deck that adds a foothold to fencing. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
.2518(g) Keep flow meter operational.
Observed flow meter that was not operational. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
.2533(e) Provide continuous forced ventilation or cross ventilation in pump room.
Observed no visible form of ventilation in pump room
.2533(3) Provide continuous forced ventilation or cross ventilation in chemical room.
Observed no form of ventilation in chemical room. |