| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
8
|
1
|
Handwashing sinks, supplied and accessible |
Yes |
No
|
No |
6-301.11 Provide soap for handwashing at each handsink. -Pf Observed no hand soap at the kitchen handsink near the entrance to the walk in coolers. -1- |
|
14
|
3
|
Food-contact surfaces: cleaned and sanitized |
Yes |
Yes
|
No |
4-602.11 Clean the equipment and utensils used with nonTCS foods as required to avoid contamination. Observed buildup inside the soda nozzles on the right side of the bar area. CDI - PIC had employee break down and clean soda nozzles during the inspection. -3- REPEAT |
|
31
|
0
|
Proper cooling methods used; adequate equipment for temperature control |
Yes |
No
|
No |
3-501.15 Quickly cool foods. Use methods such as open/vented shallow pans, large ice baths and active stirring. Cold air must flow around product to remove the heat. -Pf Observed tightly lidded cooling house made chipotle ranch dressing and sliced turkey. CDI - PIC loosened lids to vent. -0- |
|
35
|
0
|
Food properly labeled: original container |
No |
No
|
No |
3-302.12 Label all working containers of food (oils, spices, salts) except food that is easy to identify such as dry pasta. Observed unlabeled squeeze bottles of dressings and sauces in the flip top near the chicken prep sink. -0- |
|
38
|
0
|
Personal cleanliness |
No |
No
|
No |
2-303.11 Remove jewelry on hands and arms while preparing food. A plain ring, such as a wedding band, is allowed. Observed food employee wearing a watch while preparing food -0- |
|
42
|
1
|
Utensils, equipment and linens: properly stored, dried and handled |
No |
Yes
|
No |
4-903.11 Store cleaned equipment, utensils, linens and packages in a clean, dry location and at least 6 inches off the floor. Observed cleaned linen stored in direct contact with chemicals in bar area chemical cabinet. -1- REPEAT |
|
43
|
0.50
|
Single-use and single-service articles; properly stored and used |
No |
Yes
|
No |
4-904.11 Display and handle single-use and single-service articles to prevent contamination. Observed exposed lip on stacked cups near out of use dispenser. -.5- REPEAT |
|
46
|
0
|
Warewashing facilities: installed, maintained and used; test strips |
No |
No
|
No |
4-603.16 Rinsing Procedures - C A rinse solution shall immediately follow a wash solution and immediately precede a sanitizing solution when using a 3-comp sink for manual warewashing. -0- |
|
49
|
0
|
Plumbing installed; proper backflow devices |
No |
No
|
No |
5-205.15 Maintain a plumbing system in good repair. Observed broken sink stopper in the rinse compartment of the 3-comp sink. -0- |
|
53
|
1
|
Physical facilities installed, maintained and clean |
No |
Yes
|
No |
6-501.11 Floors, walls, and ceilings including the attachments such as soap and towel dispensers; light fixtures; and heat/ac vents shall be maintained in good repair. Observed hole in the wall in the candy room, damaged cabinet floor of chemical cabinet in the bar and water damaged ceiling tiles in the chemical storage room. REPEAT -1-
6-201.11 Floors, walls and ceilings shall be designed, constructed, and installed so they are smooth and easily cleanable. Observed unfinished pasteboard wall installed in the chemical storage room. |