Water quality: pool water pH |
No |
No
|
No |
.2535(1) Maintain pH at 7.2 to 7.8. Observed pH of spa at 8.4 when tested. CDI- CPO added acid to pool, corrected pH to 7.4 during inspection. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Observed facility not keeping temperature records for spa. Observed facility not consistently checking main drain covers every day. Issued ITS, C Elmore to follow up around 2/5/22. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
.2537(b) All gates and doors shall be self-closing, self-latching. Observed women's bathroom exit door to the spa to b self closing but unable to self latch due to damage. ITS issued, expires 2/5/22 |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
.2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor. Observed an open bag of soda ash on the ground in the pump room. |