5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Observed no Cyanuric Acid recording for last several weeks.
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Observed gate not self closing at deep end of pool.
Observed door not self latching or alarmed.
Observed fence with gaps greater than 2 inches in field and behind fireplace.
.2528(a) Maintain 2" or less under fence and/or gate (post-May 2010).
.2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Observed chip in deck near depth marker on sunshelf near fireplace.
Observed one no diving tile at sunshelf cracked.
.2537(2) Decks shall be kept in good repair. |