Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameVILLAGE AT COMMONWEALTH APARTMENTS
Address1308 LORNA ST
 
City/State/ZIP
CHARLOTTE NC 28205
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 10/4/2017
Final Score @ Grade
20
General Comments5) Total alkalinity and cyanuric acid missing in records for over a week when operator was absent. Record total alkalinity and cyanuric acid weekly. All other records correct. 15) Ring buoy starting to peel on back. Keep in good repair to maintain U.S. Coast Guard Approved buoy. Keep rope accessible to ring buoy at all items. 18) Chairs covering 'WARNING: NO LIFEGUARD ON DUTY' signs. Keep clearly visible. Operator moved chairs. CDI.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Some debris and toy in skimmer basket. Keep kept clean and free of debris. Operator cleaned basket. Corrected during inspection (CDI).
9 4 Pool maintenance: depth markings and no diving markers or signs visible and properly located No No No Depth markers read "6 in". Depth markers shall include word "feet" or symbol "ft". Replace tiles with correct depth markings to maintain every 25 ft or less. Issued 30 day Intent to Suspend.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Two handrails loose. Keep tight.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Handle on gate is less than 45", measured from ground and protrudes from gate more than 2 inches. Eliminate handhold/foothold. Two gates not self closing, self latching. Ensure gates are self-closing and self-latching. Latch on back gate into grassed area is less than 54 inches. Repair to meet latch requirements. Issued 30 day Intent to Suspend.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Chairs within 6 feet of pool. Maintain 6 foot deck clearance to prevent trip hazards. Operator moved chairs. CDI.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Chemicals being stored in pump room. Store in approved chemical storage room.