Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameCONRAD AT CONCORD MILLS
Address9015 KINGS GRANT RD
 
City/State/ZIP
CHARLOTTE NC 28262
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 10/11/2023
Final Score @ Grade
24
General CommentsInspection conducted with CPO Nicholas Short. Offset at main gate by pump room. Maintain decks with no gaps or offsets > 1/2”. Intent to suspend issued 5) 16)

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Pool has been closed for the last month, no recent records. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity. - Intent to suspend item.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No One weir missing. .2518(k) Replace missing weir.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Ladder loose. Ladder missing endcap. .2521 Install ladders per manufacturer instructions. Both handrails loose. .2521 Install handrail per manufacturer instructions.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Gate by restroom catches on sidewalk, not self-closing and self-latching. .2528(a) Access gates shall swing away from the pool and be self-latching, self-closing. - Intent to suspend item.
22 6 Premises: emergency telephone provided No No No Not able to call back to Kings III call box. .2530(f) Emergency phone shall remain operable. - Will follow up with facility to ensure issue is corrected.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Fan off in chemical storage room. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room. Fan off in pump room. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room.
28 2 Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted No No No Shower sign not posted. .2526(a) Post a shower sign visible upon entrance to the pool.