NameCONRAD AT CONCORD MILLS
Address9015 KINGS GRANT RD
 
City/State/ZIP
CHARLOTTE NC 28262
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 5/15/2023
Final Score @ Grade
32
General CommentsPre-permit inspection conducted with CPO Roger Malone. *NOTE* per spec sheet for glass tables, glass is tempered. Offset at main gate. Maintain decks with no gaps or offsets > 1/2”. Door frame to restroom heavily damaged. Maintain in good condition. Pool recently replastered. Observed VGB 2017 Aquastar 1216xxx main drain covers installed. Facility re-installed previously approved VGB 2008 Aquastar A10RCFRxxx drain covers for gravity drains in the fountain. Will need to replace these covers when they expire. Pre-permit inspection did not pass 3) 6) 12) 21) 22) 24) There is a $100 re-inspection fee that must be paid prior to scheduling a re-inspection by calling our office (980-314-1620) and paying with a credit card.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No pH 8.1. .2535(1) Maintain pH at 7.2 to 7.8. - Pre-permit item.
6 6 Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ No No No PDSC form does not match what was installed. Observed VGB 2017 Aquastar 1216xxx drain covers installed on pool wall for feature pump. .2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance. - Pre-permit item. Observed pop-up covers on skimmer equalizer lines. Lines plastered over on pool wall. Must be abandoned per state guidelines per PDSC form. .2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance. - Pre-permit item.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Ladders loose. .2521 Install ladders per manufacturer instructions.
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No Eyeball fitting missing on auto-fill line. .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. - Pre-permit item. Overflow grate broken. .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. - Pre-permit item.
21 4 Premises: pool and deck lighting provided at pools that operate at night No No No One underwater light not fully installed. Other light with crooked retaining screw. .2524(c) Install lighting fixtures per manufacturers instructions such that they do not present a hazard to the public. - Pre-permit item.
22 6 Premises: emergency telephone provided No No No Not able to hear Kings III operator. .2530(f) Emergency phone shall remain operable. - Pre-permit item.