Hot water supplied and maintained as required in all other areas: .2815, .2836 |
No |
No
|
No |
15A NCAC 18A .2815 (e) Hot water shall be maintained between 80°F and 110°F at handwashing sinks accessible to children. Observed hot water at 51F at bathroom hand sink. Ensure hot water is between 80-110F in areas accessible to children. REPEAT |
|
20
|
0
|
No identified lead poisoning hazards in accordance with NCGS 130A-131.7(7): .2816 |
No |
No
|
No |
General Comment:
15A NCAC 18A .2816 (b) (1) Child care operators, as defined under G.S. 110-86(7), shall test, once every three years, all water outlets used for drinking or food preparation. Samples shall also be collected and tested within 30 calendar days of completion of any renovations or repairs that may impact the facility's drinking water infrastructure, such as repair or replacement of all or part of drinking water service lines or faucets, at impacted outlets. The operator shall provide documentation of testing results for review by the Department during each unannounced routine sanitation inspection. Water testing for lead past due. Owner stated they have sent in the samples and are waiting for the results. |
|
26
|
2
|
Approved cleaning solution and approved disinfectant provided; test kit available when required: .2817, .2818, .2819, .2820, .2836 |
No |
No
|
No |
15A NCAC 18A .2812 (i) An approved disinfectant shall be provided for cleaning purposes. When a chlorine solution is prepared by a child care center employee for use as an approved disinfectant, then the solution shall be prepared for use within 24 hours, and a testing method shall be used to ensure compliance with the prescribed chlorine concentration (500 -800 ppm). Observed one of two disinfectant solutions at 0ppm. Ensure disinfectant solutions are 500-800ppm. |