Violation Item Demerits Violation Description CDIRVRComments
22 3 Proper cold holding temperatures No No No REPEAT: 3-501.16(A)(2) Maintain TCS foods in cold holding at 41 F or less. - P. Observed various TCS applicable foods cold holding above 41 F degrees on make top and lowboy unit. Refer to temperature chart. Make top was verified to be in good repair as several foods were found to be temping < 41 F degrees. According to the PIC, items in make top came from the WIC an hour prior to inspection. Meanwhile, the ambient air temperature inside the lowboy registered at 57 F degrees. PIC could not determine when food had been placed into the lowboy unit. PIC was aware that the unit was in disrepair and advised EHS that a Phoenix Heat & Air specialist assessed it back on 1/31/24. It was discovered that the unit’s thermometer is malfunctioning and a replacement part has been ordered. ETA is expected to be between 2-3 weeks. CDI - Food from lowboy unit voluntarily discarded by PIC. All items with the exception of salad were transferred to the WIC to cool down. Salad was utilized for the remainder of lunch. Staff instructed to discontinue use of entire prep unit (which includes the lowboy). VR IS REQUIRED. -3-
47 1 Equipment, food & non-food contact surfaces approved, cleanable, properly designed, constructed & used No Yes No REPEAT: 4-501.11 Maintain equipment in good repair. Observed cold holding drawers and reach-in unit under salad station not in use and waiting for repair. Facility utilizing additional cold holding equipment and walk-in cooler until equipment is repaired. Also observed damaged gaskets at both upright reach-in freezer and lowboy unit. Repair. -1-
51 0 Plumbing installed; proper backflow devices No No No 5-205.15 Maintain a plumbing system in good repair. Observed water leaking out from prep sink faucet when equipment is turned off. Repair. -0-
54 1 Garbage & refuse properly disposed; facilities maintained No Yes No REPEAT: 5-501.114 Drains in dumpsters and waste containers shall have drain plugs in place. Observed no drain plug at dumpster. -1-
55 0 Physical facilities installed, maintained & clean No No No 6-501.114 Discard items and litter stored on the premises as they are not necessary to operation and maintenance. Observed old warmer cabinet, shelving unit and miscellaneous equipment at dumpster pad as well as two non-functional fryer units in kitchen. Equipment no longer necessary for facility operation. Remove. -0-