NameAPARTMENTS AT HOLLY CREST
Address10621 HOLLY VILLAGE CIRCLE
 
City/State/ZIP
HUNTERSVILLE NC 28078
Premise Type55 - Year-Round Spa
CountyMecklenburg
Inspection Date 4/9/2025
Final Score @ Grade
30
General CommentsInspection conducted with Johnathan Windham. Advised CPO Frankie Moffit of findings. Intent to suspend issued 5) 14) 16) 23) 24)

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No No cyanuric acid checks. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. - Intent to suspend item.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Skimmers turned off in the pump room. .2518(k) Skimmers shall be operable. - Intent to suspend item.
14 4 Pool maintenance: spa timer working properly No No No Spa timer > 15 minutes. .2537(b) Spa times shall not exceed 15 minutes without manual resetting. - Intent to suspend item.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Fence < 48” high in places, mostly due to pine straw that was added. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. - Pre-permit item.
23 4 Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 No No No Erosion chlorinator does not appear to be installed according to manufacturer’s instructions. .2535(6) Provide NSF approved automatic chlorinator installed per manufacturer instructions. - Intent to suspend item.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Fencing around heater < 48” high in places. .2525(b) Heaters shall be equipped with thermostatic controls capable of assuring that the maximum operating temperature of heated public swimming pools other than spas does not exceed 90 degrees Fahrenheit. Such controls shall be accessible only to the operator. - Intent to suspend item.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Leak in the pump room. .2533(d) Pump room floor shall be kept dry and free of standing water. Lights not working in pump room. .2533(b) Provide sufficient lighting in pump room. Lights not working in chemical storage room. .2534(6) Provide sufficient lighting in chemical storage room. Fan not working in chemical storage room. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room.
26 2 Equipment room: valves and pipes identified by color codes or labels No No No Some piping not labeled. .2518(d) Piping and valves shall be labeled with color codes or labels.
27 2 Equipment room: filter backwash discharged through an air gap No No No Provide air gap for backwash. .2513(b) Filter backwash shall be discharged through an air gap.