Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameAPARTMENTS AT HOLLY CREST
Address10621 HOLLY VILLAGE CIRCLE
 
City/State/ZIP
HUNTERSVILLE NC 28078
Premise Type55 - Year-Round Spa
CountyMecklenburg
Inspection Date 4/27/2023
Final Score @ Grade
22
General CommentsInspection conducted with CPO Bennan Smith and CPO Dani Nixon. Spa recently replastered, gap around the bottom of one of the SDX2 covers on the spa wall. Ensure cover is installed correctly over the sump. Holes in the deck where ADA lift was. Recommend replacing ADA lift or filling in holes to eliminate trip hazard. Intent to suspend issued 5) 16) 20) Permit expires on 4/30/2023. Will return on 5/1/2023 to verify intent to suspend items have been corrected.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No New log sheet does not have a place for main drain or temperature checks. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. - Intent to suspend item.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No One skimmer basket cracked. .2518(k) Replace missing or damaged skimmer basket. - Corrected.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Pine straw recently added, fence as short as 45” high in places. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. - Intent to suspend item.
20 4 Premises: caution signs posted at hot water spas No No No Spa safety signage missing. .2532(16) Provide signage requiring a shower for each user before entering the spa and prohibiting oils, body lotion, and minerals in the water. - Intent to suspend item. .2532(15) Provide Caution sign in 1/2" lettering 1/2" in height according to Rule .2532(15). - Intent to suspend item.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter stuck. .2518(g) Keep flow meter operational. - Corrected.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Leak in the pump room. .2533(d) Pump room floor shall be kept dry and free of standing water.