Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameAPARTMENTS AT HOLLY CREST
Address10621 HOLLY VILLAGE CIRCLE
 
City/State/ZIP
HUNTERSVILLE NC 28078
Premise Type55 - Year-Round Spa
CountyMecklenburg
Inspection Date 11/13/2017
Final Score @ Grade
18
General Comments21) Unable to test underwater lights. Ensure that underwater lights function. Immediate suspension issued 23) Contact Will Harrison (704-507-6824) for reinspection when issue has been corrected.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Both skimmers missing weirs. Install functional weirs. - Intent to suspend item.
14 4 Pool maintenance: spa timer working properly No No No Spa timer more than 15 minutes. Timer shall turn off jet pump within 15 minutes of activation. - Intent to suspend item.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No One gate not self-latching. Provide gates that are self-closing and self-latching. - Intent to suspend item.
23 4 Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 No No No Spa does not have a chlorinator installed. Chlorine tablet in the skimmer basket. Use NSF approved chlorinator to chlorinate the spa. - Immediate suspension item.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Chemicals stored in the pump room. Newly installed liquid chlorine and acid feeder for pool with drums of chemicals in the pump room. Store all chemicals in the chemical storage room. - Intent to suspend item. General storage in pump room. Provide at least 3 feet clear walkway around equipment.