| CDI=Corrected During Inspection | |
R=Repeat Violation | |
VR=Verification Required | |
|
|
| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Multiple weirs missing.
.2518(k) Replace missing weirs.
*permit item |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Observed ladders missing rubber end caps. Replace.
.2521 Install ladders per manufacturer instructions. Keep in good repair |
|
13
|
4
|
Pool maintenance: contrasting band on steps and benches |
No |
No
|
No |
Over 3 inches from pool wall to contrasting band on stairs.
.2521(b) Provide at least 2" painted contrasting color band to edge of stair treads.
.2521(b) Tile shall be no more than one inch from the edge of the tread or adjacent tiles.
*Permit item |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Rope on buoy too short at time of inspection.
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. New rope added and cut to 42’. Corrected. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Chairs within 6’ of pool.
.2522(a) Provide 6 ft of clear walking space around the outdoor pool at all times. Operator moved and corrected. |
|
21
|
4
|
Premises: pool and deck lighting provided at pools that operate at night |
No |
No
|
No |
Lighting fixture not affixed to wall. .2524(c) Lighting fixtures shall not present a hazard to the public.
*permit item |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Flow meter not operation.
.2518(g) Keep the flow meter operational.
*Permit item |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Chemicals in pump room. No 3’ clearance around equipment. Pool built 1985.n .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
.2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. |
|