NameFOREST AT CHASEWOOD, THE
Address1600 CHASEWOOD DRIVE
 
City/State/ZIP
CHARLOTTE NC 28212
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 8/25/2026
Final Score @ Grade
30
General Comments30 Day Intent to Suspend (ITS) for lighting fixture affixed to wall, weirs and flow meter. Allowing until 2027 permitting season to correct contrasting color bands at stair entry. If bands are not corrected, pool will NOT be issued permit in 2027. “W” ITS status Updated CPO Jonathon Montalvo No night swimming, Pool not heated. Pump remains at speed 3, 3110 RPM

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Multiple weirs missing. .2518(k) Replace missing weirs. *permit item
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Observed ladders missing rubber end caps. Replace. .2521 Install ladders per manufacturer instructions. Keep in good repair
13 4 Pool maintenance: contrasting band on steps and benches No No No Over 3 inches from pool wall to contrasting band on stairs. .2521(b) Provide at least 2" painted contrasting color band to edge of stair treads. .2521(b) Tile shall be no more than one inch from the edge of the tread or adjacent tiles. *Permit item
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Rope on buoy too short at time of inspection. .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. New rope added and cut to 42’. Corrected.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Chairs within 6’ of pool. .2522(a) Provide 6 ft of clear walking space around the outdoor pool at all times. Operator moved and corrected.
21 4 Premises: pool and deck lighting provided at pools that operate at night No No No Lighting fixture not affixed to wall. .2524(c) Lighting fixtures shall not present a hazard to the public. *permit item
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter not operation. .2518(g) Keep the flow meter operational. *Permit item
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Chemicals in pump room. No 3’ clearance around equipment. Pool built 1985.n .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.