Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameFOREST AT CHASEWOOD, THE
Address1600 CHASEWOOD DRIVE
 
City/State/ZIP
CHARLOTTE NC 28212
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 10/14/2021
Final Score @ Grade
24
General CommentsCPO AGREED TO EMAIL COPY OF REPORT NO SIGNATURE DUE TO COVID-19 PRECAUTIONS. CONTINUE TO FOLLOW ALL RELEVANT COVID RULES ENSURE THAT THE 911 CALL BOX SPEAKER IS EVALUATED, IT WAS SUBJECT TO REPEATED VOLUME DROPS DURING TESTING WITH 2 DIFFERENT OPERATORS.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
2 6 Water quality: disinfectant residual provided by No No No .2535(4) Maintain chlorine at least 1.0 ppm. Observed 0.0ppm chlorine at the pool. Pool must maintain 1ppm chlorine for safety. Chlorine cannot be maintained for normal operation by using shock, it must be feed in through the chlorination system. I.S. Issued. Pool is closed by order of the Health Department. Contact C. Elmore at 704-507-6814 to verify correction. Pool cannot reopen without Health Department approval.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Cyanuric Acid not to exceed 100ppm. Observed gaps in the log book. Keep the log book properly. No permit action taken.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Observed 1 ladder to be missing a rubber bumper foot. Replace the foot.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Observed throw rope to be 46 feet long. Corrected to 42 feet as is required for this pool. -C.D.I.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Observed fence to be built prior to 2010. Fence is not built to current spec. No permit action taken.
27 2 Equipment room: filter backwash discharged through an air gap No No No Observed no air gap at the backwash line.