5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Observed log book to have last written entry on 10/20/26. Daily and weekly checks must be done and recorded. I.T.S. ISSUED |
|
6
|
6
|
Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ |
No |
No
|
No |
Observed vacuum attachment left on pool wall port. Observed some suction from port. Temporary plug was installed. Provide proper threaded port cap. I.T.S. ISSUED |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Observed 2 weirs missing out of 6 skimmers. Replace them. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Observed 1 ladder missing the rubber feet. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Observed a gap on a fence gate larger than 4" within 18 inches of the latch. Block this gap and allow no openings greater than 1/2" in the barrier. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
Observed no backwash air gap. |