Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameAPARTMENTS AT HOLLY CREST
Address10621 HOLLY VILLAGE CIRCLE
 
City/State/ZIP
HUNTERSVILLE NC 28078
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 7/21/2025
Final Score @ Grade
42
General CommentsInspection conducted with CPO Ricardo Trujillo. Ricardo is the new CPO. Updated our files. Pool heated. Heater off at the time of inspection. Did not check pool temperature. New management company. Emailed manager a copy of the application. Will need to update and return it to our office so we can update our files. Ensure pool is properly maintained and pump is operating to achieve minimum turnover. Filter pressure high, flow meter reading only 40 GPM, very little flow in skimmers. Some pool rules signs are mostly covered by bushes. Ensure pool rules signs are easily visible. Immediate suspension issued 1) 2) Contact Will Harrison (704) 507-6824 for re-inspection once issues have been corrected.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
1 6 Water quality: water clear enough to clearly see bottom of pool and pool drain No No No Pool very cloudy. Not able to clearly see the main drains. .2535(2) Main drains must be clearly visible from the pool deck. - Immediate suspension item.
2 6 Water quality: disinfectant residual provided by No No No No free chlorine in the pool. .2535(4) Maintain chlorine at least 1.0 ppm. - Immediate suspension item.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No No records since 7/14. No cyanuric acid or main drain checks. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity. - Intent to suspend item.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Observed debris on pool floor. .2537(14) Keep pool surface and pool floor free of debris. - Intent to suspend item.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Observed one weir missing. .2518(k) Install functional weirs. Most skimmer baskets with leaves. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Intent to suspend item. Very little or no flow in all of the skimmers. .2518(k) The flow-through rate through any one skimmer shall be between 20 GPM and the maximum flow rated under NSF 50. - Intent to suspend item. Water level above the skimmers. .2518(k) Water level shall be maintained to assure skimmers are operable. - Intent to suspend item.
9 4 Pool maintenance: depth markings and no diving markers or signs visible and properly located No No No Depth marker covered up by basketball goal. .2523(b) Provide depth markers spaced not to exceed 25 feet when measured along the perimeter of the pool. - Intent to suspend item.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Piece of coping chipped off by sunshelf. .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. - Intent to suspend item. Basketball goal beside pool. .2522(a) Provide 8 ft of clear walking space around the pool at all times (>1600 sq. ft). - Intent to suspend item.
23 4 Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 No No No Automatic controller out of liquid chlorine. .2535(6) Provide NSF approved automatic chlorinator installed per manufacturer instructions. - Intent to suspend item.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Leak in the pump room. .2533(d) Pump room floor shall be kept dry and free of standing water.
27 2 Equipment room: filter backwash discharged through an air gap No No No No air gap for backwash. .2513(b) Filter backwash shall be discharged through an air gap.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No No soap in unisex restroom. No soap in men’s restroom. No soap in one dispenser in women’s restroom. .2526(j) Provide soap and soap dispenser, no glass, at each sink.