Premises Information

Return to Inspections
NameAPARTMENTS AT HOLLY CREST
Address10621 HOLLY VILLAGE CIRCLE
 
City/State/ZIP
HUNTERSVILLE NC 28078
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 9/21/2022
Final Score @ Grade
22
General CommentsVisit conducted with inspector Michael Hackworth and CPO Brennan Smith. Wall tiles dirty, difficult to read depth markers. Clean wall tiles regularly. Starguard Main Drain covers expire December 5, 2022. Replace with ANSI/APSP/ICC-16 2017 approved main drain covers and provide updated PDSC form to our office prior to main drain expiration. Pump motor for filtration pump changed in the last 2 years. Will need a an electrical permit and passing electrical inspection prior to 2023 pool permit being issued. Pump motor for feature pump looks like it is older. Two electrical permits obtained in 2018, one failed inspection and one was cancelled. Pump shut off by operator. Will need to keep pump off until obtain an electrical permit and passing inspection from Mecklenburg County Code Enforcement. Verified underwater lights for the pool work. Photocells for deck lights are not accessible, will make a return visit at night to verify sufficient lighting for night swimming permit. Intent to suspend issued 17) 24)

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
6 6 Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ No No No PDSC form does not match what is on file. Wrong main drains, four 6HPHA and one 4HP equalizer line covers installed. .2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance. - Operator filled out an updated PDSC form.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No One skimmer basket cracked. .2518(k) Replace missing or damaged skimmer basket. Missing 2 of 5 weirs. .2518(k) Install functional weirs.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No One set of recessed steps with top two steps cracked. .2521 Install steps per manufacturer instructions.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Umbrella on sun shelf extends into walkway around pool. .2522(a) Provide 6 ft of clear walking space around the pool at all times. - Corrected, removed by CPO. Set of lounge chairs along one side of the pool < 6 feet from pool edge. .2522(a) Provide 6 ft of clear walking space around the pool at all times. - Intent to suspend item.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter stuck. .2518(g) Keep flow meter operational. - Intent to suspend item.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Chemicals stacked on top of each other. Bag of soda ash wet from chemical spill. .2534(5) Chemicals shall be stored as to prevent a reaction and permit for easy clean-up. Trash, broken chair, other debris strewn across the pump room floor. Have to walk over items to access equipment. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. Some chemicals stored in the pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.