Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameAPARTMENTS AT HOLLY CREST
Address10621 HOLLY VILLAGE CIRCLE
 
City/State/ZIP
HUNTERSVILLE NC 28078
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 10/15/2018
Final Score @ Grade
20
General CommentsIntent to Suspend issued for gate latch heights, opening at gate, and heater outside fence. Replace ring buoy with USCG approved ring buoy within 1 week.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Ring buoy rope in disrepair - torn apart and tied together. Replaced with 50 ft rope at time of inspection. .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Grab rope on USCG approved ring buoy beginning to degrade due to weather. Still intact. Replace within 1 week. .2530(a) Provide USCG approved ring buoy. A rescue tube with lifeguard may be substituted for ring buoy.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No New magna-latch gate latches installed at 52" measured from ground. .2528(a) Gate latches shall be 54" in height measured from ground to top of latch. Intent to Suspend issued. Openings in fencing >2" where old hardware was removed for door handles. .2528(b) Decorative cut-outs on fence and/or gate shall not exceed 1.75 inches. Intent to Suspend issued. Heater outside of pool fence providing foothold. Eliminate foothold. .2528(b) Horizontals shall not be located less than 45" in height.
22 6 Premises: emergency telephone provided No No No Emergency phone not visible upon entry to swimming pool. Additional signage added during inspection. Written in to pool rules signs at entry areas. .2530(a) Emergency phone shall be visible from all areas inside pool enclosure.
23 4 Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 No No No Facility has Chlorking Salt system installed. System capable of 5 lbs/day. Required system for salt 12 lbs/day due to sizing of pool. Salt is not approved as primary chlorination. .2535(6) Provide NSF approved automatic chlorinator installed per manufacturer instructions. Liquid chlorinator verified during inspection. Operator will switch to supplementary salt and primary chlorine through liquid.