22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
.2530(f) Emergency notification systems must provide 24 hr. monitoring, be capable of routing calls to 911, and be able to electronically transfer Automatic Number and Locator Identification for the phone.
Observed Kings III phone that had operator to connect to 911, but 911 does not have same address and phone number for pool. 911 has pool at 14185 Ballantyne Village Way and phone number as 661.701.9628 which does not match what’s listed on board or in Kings III records.
Unable to use number to call 911. Kings III was able to allow phone calls to come through to box at pool deck.
Permit denied until remaining issue repaired. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
.2518(h) Provide approved pump in good repair.
Observed pump in equipment room that was a Pentair EQ500 but PDSC form states it is a Pentair CH-50. PIC stated it was changed a year ago. Updated PDSC form needs to be submitted for approval.
Permit denied until issues resolved.
.2518(e) Provide a spare basket for pump. Observed no spare pump basket |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
.2526(m) Keep restrooms and fixtures clean and in good repair.
Observed restrooms in need of cleaning. |