Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameMARQUIS OF CARMEL VALLEY
Address6905 POPPY HILLS LN
 
City/State/ZIP
CHARLOTTE NC 28226
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 10/22/2025
Final Score @ Grade
24
General CommentsInspection conducted with Glenn. Bonding wire not attached to pump motor. G.S. 130A-2(3) Bonding wire shall be attached to the pump motor by a certified electrician. - Corrected. Pool throw rope listed in our system as 24 ft. Appears to be less than 1.5x the width of the pool. Will follow up with the facility if changes are needed. Electricians working to correct an issue in the pump room. Will check that automatic feeder shuts off when the pump is off on my return visit. Facility permitted for night swimming. Did not verify lighting, will check on my return visit. Facility has an automatic chemical feeder. Recommend having the chemical controller recalibrated. Immediate suspension issued. 3) Contact Will Harrison (704) 507-6824 to schedule re-inspection once issues have been corrected.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No PH 7.0. Operator adjusted, but went down to 6.8. .2535(1) Maintain pH at 7.2 to 7.8. - Immediate suspension item.
9 4 Pool maintenance: depth markings and no diving markers or signs visible and properly located No No No Depth marker installed on expansion joint is loose. .2523(a) Provide depth markers on pool walls and pool deck next to the swimming pool. - Intent to suspend item.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Handrails missing escutcheon plates. .2521 Install handrails per manufacturer instructions.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Pre-2010 fence < 48” high in places. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. Pre-2010 fence with gaps > 4” under the fence at drainage basin. .2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010).
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter stuck. .2518(g) Keep flow meter operational. - Corrected.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Items stored next to pump equipment. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
27 2 Equipment room: filter backwash discharged through an air gap No No No No air gap for backwash line. .2513(b) Filter backwash shall be discharged through an air gap.