3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
pH 8.0 at time of inspection. .2535(1) Maintain pH at 7.2 to 7.8. Operator adjusted feeder (Add acid, to lower pH) and corrected to 7.3 |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
One gate not latching and fence height less than 48" in areas where dirt from construction and mulch from landscaping has piled up on outside of fence by spa area at time of inspection.
.2528(a) Pool fence shall be at least 48" in height measured from outside of barrier.
.2537(b) All gates and doors shall be self-closing, self-latching.
Operator cleared out dirt and mulch for fence height and adjusted gate to self-latch. Corrected. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Items within 3' clearance of piping and equipment. Some chemicals in pump room. Water on floor of pump room under pumps.Pool built prior to 2004. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
.2533(d) Pump room floor shall be kept dry and free of standing water. |
|
28
|
2
|
Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted |
No |
No
|
No |
Shower off due to cold weather at time of inspection. .2526(h) Shower(s) shall be provided. |