Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameMARQUIS OF CARMEL VALLEY
Address6905 POPPY HILLS LN
 
City/State/ZIP
CHARLOTTE NC 28226
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 9/15/2021
Final Score @ Grade
28
General CommentsImmediate Suspension issued for emergency phone and updating PDSC form. Pool MUST REMAIN CLOSED until suspension is lifted by Health Dept. Contact Marie Daley at 704-507-6806 when in compliance to lift suspension. Doors onto pool deck is permit item that will be verified at return visit. Verified lights for Night Swimming Inspection with Glenn Decker No signature due to COVID Changed to "E" Immediate Suspension status

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
6 6 Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ No No No Pool pump observed at time of inspection Challenger CHII-NI-3FE, PDSC has Challenger CHII-NI-3F. Pump curve is same for both, but update to reflect correct pump. Pump has not been changed according to CPO, administrative error. 2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance. *Permit item
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Tread missing on top ladder step. .2521(b) Ladders shall have slip-resistant tread.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Buoy behind palms/bushes at time of inspection. Keep accessible. .2530(a) Lifesaving equipment should be conveniently located. Operator moved and corrected.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No One door from club house not latching or alarmed at time of inspection. Clubhouse under renovation. .2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. *30 Day Intent to Suspend (ITS) item
22 6 Premises: emergency telephone provided No No No Emergency phone not working at time of inspection. .2530(f) Emergency phone shall remain operable. *Issued Immediate Suspension. Contact Marie Daley at 704-507-6806 when in compliance to lift suspension.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Items within 3' clearance of piping and equipment. Some chemicals in pump room. Pool built prior to 2004. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Clubhouse under construction. No sinks, handwashing fixtures available. Port-a-john outside restroom. Provide sink, water, soap, hand drying at restrooms.