NameMARQUIS OF CARMEL VALLEY
Address6905 POPPY HILLS LN
 
City/State/ZIP
CHARLOTTE NC 28226
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 4/19/2018
Final Score @ Grade
16
General CommentsIssued local permit. No Night Swimming.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Skimmer baskets with leaves and debris. Keep clean. Operator cleaned. Corrected.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Grills placed in pool deck area making body hook and ring buoy inaccessible. Keep accessible at all times in case of emergency. Operator moved items for accessibility. Designated new permanent location for life saving equipment. Corrected. *Note: Becketts starting to separate from buoy. Replace before next inspection to maintain US Coast Guard Approved status buoy (Rope 24')
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Gap on side gate greater than 1/2" within 18" of inside door latch (3.5"). .2528(a) Gate latches located at less than 54" shall require the use of key, combination lock or card reader or be located on the inside of the gate at least three inches below the top of the gate with no greater than 1/2" witihn 18" of latch mechanism.Operator installed solid piece to create 18" no gaps greater than 1/2". Corrected. Door from clubhouse not self-latching. Ground levels doors must self-close, self-latch or have audible alarm. Operator corrected door to self-close-self-latch.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Water on floor in pump room. Pump room floor shall be kept dry and free of standing water. Maintain 3' clear walking space around equipment.