Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameARCADIA STUDENT LIVING
Address707 SANCTUARY PLACE
 
City/State/ZIP
CHARLOTTE NC 28213
Premise Type55 - Year-Round Spa
CountyMecklenburg
Inspection Date 6/8/2020
Final Score @ Grade
16
General CommentsInspection conducted with Matt Empson and Terry with Caribbean Pool Services. Due to COVID-19 precautions, inspection was not signed by the operator. 911 had difficulty hearing me. Recommend adjusting the volume. This was noted on the previous inspection. Housing on filtration pump has been changed, no label on new housing for Hayward TriStar pump. 3/4 HP motor observed. Broken glass between pool and spa. Ensure that pool and spa deck are free of broken glass. Corrected. Recommend thoroughly cleaning the pool and spa. Office and restrooms closed due to COVID-19 precautions. Did not inspect restrooms. Would recommend providing restrooms to bathers. Permit issued. No Night Swimming “Executive Order No. 141 or subsequent Orders are in effect unless such Orders are rescinded or superseded by another applicable Order.”

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No pH 7.0. .2535(1) Maintain pH at 7.2 to 7.8. Corrected to 7.4
14 4 Pool maintenance: spa timer working properly No No No Spa timer > 15 minutes. .2537(b) Spa times shall not exceed 15 minutes without manual resetting. Corrected.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Main gate standing open, gate spring stuck underneath it. Side gate does not latch. .2537(b) All gates and doors shall be self-closing, self-latching. - Corrected. Some bent pickets by main gate, 5" gaps in fence. .2528(a) Provide no openings in fence and/or gate greater than 4"x4". Corrected.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Light not working in chemical storage room. .2534(6) Provide sufficient lighting in chemical storage room.