Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameARCADIA STUDENT LIVING
Address707 SANCTUARY PLACE
 
City/State/ZIP
CHARLOTTE NC 28213
Premise Type55 - Year-Round Spa
CountyMecklenburg
Inspection Date 12/11/2019
Final Score @ Grade
34
General Comments911 had difficulty hearing me. Recommend adjusting the volume. Autofill running, water running out of the overflow. Recommend adjusting the autofill so the chemicals remain balanced and the chemical feeders don't have to run constantly. Carribean Pools had the spa jets turned off because they were running constantly. Did not test the jets. Ensure that spa timer turns off that jets within 15 minutes of activiation. Pump housing on filtration pump was changed prior to the previous inspection. No markings on Hayward TriStar pump. 3/4 HP motor observed. NOTE: Equalizer lines recently disabled. Plugs were not installed per state guidelines. Plugs are easily removable. Follow state guidelines to ensure that there are no future issues with the work done. Including draining the water below the equalizer line to remove all of the water in the line and installing plugs such that they can only be removed with a tool. There should be no stagnant water in the line. Immediate suspension issued. 3) 6) Contact Will Harrison (704-507-6824) for reinspection when issues are corrected.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No pH 8.4. .2535(1) Maintain pH at 7.2 to 7.8. - Immediate suspension item.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No No main drain checks for December. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. - Intent to suspend item.
6 6 Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ No No No Equalizer line covers have been abandoned. Do not have an approved PDSC form on file reflecting this. .2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance. - Immediate suspension item.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Skimmer basket cracked. .2518(k) Replace missing or damaged skimmer basket. - Intent to suspend item.
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No Missing one return fitting and one jet fitting. .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. - Intent to suspend item.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Back gate not self-closing. .2537(b) All gates and doors shall be self-closing, self-latching. - Intent to suspend item.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Filter multiport leaking. .2533(d) Pump room floor shall be kept dry and free of standing water.
26 2 Equipment room: valves and pipes identified by color codes or labels No No No Labels heavily worn/missing. .2518(d) Piping and valves shall be labeled with color codes or labels.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Faucet loose in men's locker room. .2526(m) Keep restrooms and fixtures clean and in good repair.