5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Weekly total alkalinity and cyanuric acid not recorded each week. .2535(11) Provide record keeping including daily records of disinfectant
residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for
cyanuric acid and total alkalinity weekly. Operator checked and corrected.
*Permit item |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Observed 2 of 5 weirs missing at time of inspection. .2518(k) Replace missing weirs.
*Permit item. Will check at return visit |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Clubhouse door not latching at time of inspection.
.2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm.
*Permit item |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Deck chipped out greater than 1/2" by 3 1/2 FT holes for poles.
.2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile.
*Permit item |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Operator unable to locate spare pump basket at time of inspection. Intelliflo VSF 011056. .2518(e) Provide a spare basket for pump.
*Permit item |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
No 3' clearance around equipment in pump room. Liquid chemicals above dry. One bag of dry chemicals fallen on floor. Pool built 2000. .2533(c) Valves and controls
shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
.2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
.2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor.
.2534(5) Chemicals shall be stored as to prevent a reaction and permit for easy clean-up. |