Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameMARQUIS AT CARMEL COMMONS
Address6818 NORTHBURY LANE
 
City/State/ZIP
CHARLOTTE NC 28226
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 3/17/2022
Final Score @ Grade
20
General Comments30 Day Intent to Suspend (ITS) issued for CPO, records, "FT" on depth marker, offsets greater than 1/2", gates self-closing, self-latching, windows onto pool deck opening greater than 4". Contact Marie Daley at 704-507-6806 when in compliance to lift ITS. Changed to "W" ITS status Inspection with Mark Rosenkrantz No signature due to COVID Discussed restroom renovations done without approval and potential issues. Forwarding to pool seniors and will send e-mail then make return visit with more information.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Weekly total alkalinity and cyanuric acid not recorded. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Unable to verify active CPO for property. .2537(c) Pool owner shall provide for the operation and maintenance of the pool by a trained pool operator. *Permit items
9 4 Pool maintenance: depth markings and no diving markers or signs visible and properly located No No No 4 FT depth marker on deck missing "FT" or "feet" .2523(c) Depth markers shall include the word "feet" or symbol "ft". *Permit item
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No One gate not latching at time of inspection. Windows from office and kitchen area of clubhouse, able to open fully, more than 4" onto pool deck. .2537(b) All gates and doors shall be self-closing, self-latching. .2528(a) Ground level windows shall not open greater than 4" on to pool deck or child protected by audible alarm. *Permit items Side of building creating horizontal less than 45" in height. Pool built '00. .2528(b) Horizontals shall not be located less than 45" in height.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Coping chipped out greater than 1/2", holes from poles greater than 1/2" and wood slat in deck has sunk down, greater than 1/2". .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. *Permit item
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No No 3' clearance around equipment in pump room. Chemicals stored in pump room. Pool built 2000. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Sink in men's restroom not working at time of inspection. Restrooms had been renovated. Flooring does not appear slip resistant, could not verify mirrors being shatterproof and observed no hose bib within 50' of restrooms. No floor drains and may not be sloped to drain. . Following up on this item regarding corrective action due to no plan approval and apartment community.