General CommentsNight Swimming lighting and photos sent via Edward Irizarry on 3/31. Contact Marie Daley 704-507-6806 regarding main drains by 4/13. At least 50% required in place. No permit will be issued until corrected. Verified pump Pentair IntellifoVSF (not IntellifoVS) 011056 3HP, 2 Aquastar R9MF, 5 Aquastar 6HPHA. Minimum flow must be 137 gpm with operable flow meter. Clubhouse being remodeled. Ensure permits are pulled and Health Dept informed, if needed regarding doors/windows onto pool deck and restrooms. Inspection with Rob Harsh No signature due to COVID

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No pH 7.0 at time of inspection. .2535(1) Maintain pH at 7.2 to 7.8. Operator added chemicals and corrected to 7.8.
6 6 Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ No No No Main drain covers both observed with 3 of 8 screws in place. Covers must be secured and installed with at least 50% of screws and according to instruction. .2539(b) All suction fittings shall be installed in accordance with the manufacturer's instructions. Allowed 7 days to correct. Failure to correct by 4/13 will result in Immediate Suspension of permit. Contact Marie Daley at 704-507-6806 when in compliance to verify.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Observed 1 of 5 weirs missing at time of inspection. .2518(k) Replace missing weirs. Operator replaced and corrected. Debris in skimmers at time of inspection..2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Operator emptied and corrected.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No No 3' clearance around equipment in pump room. Chemicals stored in pump room. Standing water on floor in pump room at time of inspection. Pool built 2000. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. .2533(d) Pump room floor shall be kept dry and free of standing water. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
28 2 Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted No No No Showers off due to colder weather at time of inspection. .2526(h) Shower(s) shall be provided. Operator turned on water and corrected.