Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameMARQUIS AT CARMEL COMMONS
Address6818 NORTHBURY LANE
 
City/State/ZIP
CHARLOTTE NC 28226
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 2/26/2020
Final Score @ Grade
14
General CommentsMain drains and skimmer equalizer covers expire April 2020. Update covers submit updated PDSC form for approval prior to expiration to avoid permit action. Contact Marie Daley for Night Swimming visit. Pool will not be permitted for Night Swimming until visit is made. Note: Showers off at time of inspection

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Weekly total alkalinity and cyanuric acid not recorded. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Operator checked and recorded. Corrected.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No One of 5 weirs missing at time of inspection. .2518(k) Replace missing weirs. Lack of severity does not warrant permit action. Operator installing new weir and sending verificationto Marie Daley at 704-507-6806.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter not operating at time of inspection. .2518(g) Keep flow meter operational. Opereator adjusted and corrected.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Chemicals stored in pump room. Pool built prior to 2004. Items around equipment. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. Observed pump room without 3 ft clear walking space. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.