Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameMARQUIS AT CARMEL COMMONS
Address6818 NORTHBURY LANE
 
City/State/ZIP
CHARLOTTE NC 28226
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 4/11/2018
Final Score @ Grade
22
General CommentsITS for No Diving, doors and holes (offset greater than 1/2") 6) Main drains have 4 of 8 screws in screw holes. At beginning of inspection debris made main drains hard to see. Operator placed vaccumm in the pool. Cleared debris. Verified drain cover with Katie Wilson, Senior pool specialist, at least half screws are in place, drain cover is secure and some drain covers do not require fasteners in the sump to connect. *Note: Annual permit will NOT be renewed on 5/1/18 unless items are in compliance. Permit will not permit ‘Night Swimming’ until an onsite visit is conducted before dawn or after dusk to meet compliance with new regulation. It can still be open during daylight hours (dawn to dusk) without an onsite visit. Lighting requirement includes: Pool illumination is sufficient to illuminate the main drains of the pool and the deck area of the pool so that it is visible at all times the pool is in use. Lighting fixtures are of such number and design to illuminate all parts of the pool, the water, the depth markers, signs, entrances, restrooms, safety equipment and the required deck area and walkways. The illumination is sufficient so that the floor of the pool can be seen at all times the pool is in use. Please contact Marie Daley at 704-507-6806 directly to schedule a visit to verify lighting is sufficient and this condition is met to update permit to allow ‘Night Swimming’.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Skimmer baskets with debris. Keep clean. Operator emptied. Corrected.
9 4 Pool maintenance: depth markings and no diving markers or signs visible and properly located No No No 'No Diving' markers are black and white international symbol. No Diving markers shall be written in four inch letters or international 6"x6" no diving in red and black on a white background. No Diving markers shall be placed at least every 25' apart. **30 Day Intent to Suspend item. Contact Marie Daley at 704-507 -6806 when items are addressed to lift ITS. **Note Annual permit will NOT be renewed on 5/1/18 until items are in compliance and may require a pre-permit inspection to re-open.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Rubber caps missing on ladder. Keep in good repair.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Door by fitness room not self-latching at time of inspection. Windows onto pool deck able to open greater than 4" if unlocked. Operator installed permanent stopper on windows. Corrected. Ground level doors shall be self-closing, self-latching or child protected by audible alarm. Ground level windows shall not open greater than 4" on to pool deck or child protected by audible alarm. **30 Day Intent to Suspend item. Contact Marie Daley at 704-507 -6806 when items are addressed to lift ITS. **Note Annual permit will NOT be renewed on 5/1/18 until items are in compliance and may require a pre-permit inspection to re-open.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Holes in deck greater than 1/2". Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. *ITS item.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Water on floor in pump room. Pump room floor shall be kept dry and free of standing water. Maintain 3' clear walking space around equipment.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Showers not working at time of inspection due to piping issues. Keep in good repair and operational.