Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameAPARTMENTS AT BLAKENEY
Address8724 WINTERSWEET LN
 
City/State/ZIP
CHARLOTTE NC 28277
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 10/20/2026
Final Score @ Grade
10
General CommentsConducted inspection with operator Ean. Immediate suspension issued for chlorine level. Pool placed on E status and must close. Call EHS Devon when item is corrected and ready to reopen. 7049981122 Flow meter has been replaced with Aquastar FlowStar flow meter with 5% accuracy on specification sheet, measured correct installation with 5x pipe diameter on inlet pipe (3 inch pipe, 15” pipe length inlet side and 2x pipe diameter on outlet side). Advised updating portion of PDSC form reflecting correct/new updated flow meter and submitting to pdsc@mecknc.gov, noting that update is for new 5% accurate flow meter only. Flow required 120-150 gpm, observed 130 gpm. Permit Restriction: 5% flow meter must remain operable. Flow required at least 120 gpm. Flow greater than 150 gpm exceeds the main drains. Suction Hazard. Const. Date: 2/26/2016 Rope Length: 50' Night Swim?: N

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
2 6 Water quality: disinfectant residual provided by No No No .2535(4) Maintain chlorine at least 1.0 ppm. Chlorine observed at 0ppm. Immediate suspension item.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Some well equipment within 3 ft of pool piping and equipment. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
26 2 Equipment room: valves and pipes identified by color codes or labels No No No Some piping not labeled. .2518(d) Piping and valves shall be labeled with color codes or labels.