NameAPARTMENTS AT BLAKENEY
Address8724 WINTERSWEET LN
 
City/State/ZIP
CHARLOTTE NC 28277
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 3/31/2026
Final Score @ Grade
10
General CommentsFlow meter has been replaced with Aquastar FlowStar flow meter with 5% accuracy on specification sheet, measured correct installation with 5x pipe diameter on inlet pipe (3 inch pipe, 15” pipe length inlet side and 2x pipe diameter on outlet side). Took picture verification. Advised updating portion of PDSC form reflecting correct/new updated flow meter and submitting to pdsc@mecknc.gov, noting that update is for new 5% accurate flow meter only. Flow required 120-150 gpm, observed 135 gpm. No night swimming. Pool not heated. Inspection with Ean Wrightson “A” Open for Business

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Records missing weekly total alkalinty and cyanuric acid. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Operator checked, recorded and corrected.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Some well equipment within 3 ft of pool piping and equipment. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
26 2 Equipment room: valves and pipes identified by color codes or labels No No No Some piping not labeled. .2518(d) Piping and valves shall be labeled with color codes or labels.
28 2 Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted No No No Shower off at time of inspection. .2526(h) Shower(s) shall be provided.