Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameAPARTMENTS AT BLAKENEY
Address8724 WINTERSWEET LN
 
City/State/ZIP
CHARLOTTE NC 28277
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 3/9/2020
Final Score @ Grade
22
General CommentsIntent to suspend permit issued for the following non-compliant items: NO SPOT IN RECORD BOOK FOR RECORDING MAIN DRAIN CHECKS, DISTANCE BETWEEN HORIZONTAL MEMBERS OF GATES IS 36 INCHES, SOME DEPTH MARKERS ON POOL DECK AND POOL WALL MISSING WORD 'FEET' OR 'FT.', AND SIGNAGE FOR "CHILDREN SHOULD NOT USE THE SWIMMING POOL WITHOUT ADULT SUPERVISION" AND "ADULTS SHOULD NOT SWIM ALONE" IS ONLY 5/8 INCHES TALL, MUST BE 1 INCH MINIMUM. CORRECT ITEMS WITHIN 30 DAYS.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Observed written records missing location to record main drain checks. Intent to suspend issued.
9 4 Pool maintenance: depth markings and no diving markers or signs visible and properly located No No No .2523(c) Depth markers shall include the word "feet" or symbol "ft". Observed some depth markings on pool deck and pool wall missing 'feet' or 'ft.' Intent to suspend issued.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528(b) Horizontals shall not be located less than 45" in height. Observed distance between horizontal members at 35 inches on all gates that lead onto pool deck. Intent to suspend issued. May correct by placing solid material between members that exceeds up to 45 inches.
18 4 Premises: lifeguards present or warning signs posted No No No .2530(c) Provide "Children should not use the swimming pool without adult supervision." in 1" lettering. Observed lettering at 5/8 inches. Intent to suspend issued. .2530(c) Provide "Adults should not swim alone." in 1" lettering. Observed lettering at 5/8 inches. Intent to suspend issued.
22 6 Premises: emergency telephone provided No No No .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Observed sign with wrong address listed and no phone number listed. CDI- updated sign provided today with correct information.