Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameELEMENT BALLANTYNE
Address15707 CLEMS CREEK LN
 
City/State/ZIP
CHARLOTTE NC 28277
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 8/5/2020
Final Score @ Grade
22
General Comments30 Day Intent to Suspend (ITS) issued for depth markers, weir and flow meter. Contact Marie Daley at 704-507-6806 when in compliance to lift ITS. Changed to "W" status. Inspection with: James Friday Report to: Element Ballantyne Maintenance ; manager@elementballantyne.com No signature due to COVID-19.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Main drain checks observed missing on records. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Operator added line and corrected.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Debris observed in skimmers at time of inspection. Weir missing in skimmer. .2518(k) Replace missing weirs. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Operator emptied skimmer baskets and corrected. *ITS item.
9 4 Pool maintenance: depth markings and no diving markers or signs visible and properly located No No No "0 FT" depth marker missing on pool wall and deck at sunshelf, greater than 25' apart. .2523(c) Depth markers shall include the word "feet" or symbol "ft". .2523(b) Provide depth markers spaced not to exceed 25 feet when measured along the perimeter of the pool. *ITS item
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Ladder missing rubber stoppers at time of inspection. .2521 Install ladders per manufacturer instructions.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter not operational at time of inspection. .2518(g) Keep flow meter operational. *ITS item
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Items and chemicals stored in pump room within 3' of equipment. Paper towels and toilet paper stored on chemicals in pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. .2534(5) Chemicals shall be stored as to prevent a reaction and permit for easy clean-up.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No No paper towels or hand drying in restroom at time of inspection. Provide hand drying for restrooms. Operator placed paper towels in restroom. Corrected.