5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Main drain checks observed missing on records.
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Operator added line and corrected. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Debris observed in skimmers at time of inspection. Weir missing in skimmer.
.2518(k) Replace missing weirs.
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Operator emptied skimmer baskets and corrected.
*ITS item. |
|
9
|
4
|
Pool maintenance: depth markings and no diving markers or signs visible and properly located |
No |
No
|
No |
"0 FT" depth marker missing on pool wall and deck at sunshelf, greater than 25' apart.
.2523(c) Depth markers shall include the word "feet" or symbol "ft".
.2523(b) Provide depth markers spaced not to exceed 25 feet when measured along the perimeter of the pool.
*ITS item |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Ladder missing rubber stoppers at time of inspection.
.2521 Install ladders per manufacturer instructions. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Flow meter not operational at time of inspection. .2518(g) Keep flow meter operational.
*ITS item |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Items and chemicals stored in pump room within 3' of equipment. Paper towels and toilet paper stored on chemicals in pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
.2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
.2534(5) Chemicals shall be stored as to prevent a reaction and permit for easy clean-up. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
No paper towels or hand drying in restroom at time of inspection. Provide hand drying for restrooms. Operator placed paper towels in restroom. Corrected. |
|