| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Records missing temperature of heated pool.
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Operator added and corrected. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
1 of 8 weirs missing.
.2518(k) Replace missing weirs. Operator replaced. Corrected. |
|
10
|
2
|
Pool maintenance: safety ropes with floats and contrasting color bands provided at shallow area breakpoints |
No |
No
|
No |
Rope missing at break point of pool. .2523(e) Provide a minimum of 3/4 inch diameter safety rope at the breakpoint.
.2523(e) Safety rope shall be marked with colored floats, 5 ft. apart or less. Operator replaced and corrected. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Half of diving board installed at deep end of pool, missing front piece, not restricted to use and no information on it. .2517 (1) Diving equipment shall be designed for swimming pool use and shall be installed in accordance
with the manufacturer's recommendations.
(2) Installation instructions and specifications shall be provided with each unit.
(3) A label shall be permanently affixed to the diving equipment and shall include:
(A) manufacturer's name and address;
(B) board length;
(C) type of diving board;
Operator restricted use of board as not for use with cone and signage. If this is used the above will be brought into compliance. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Back gate not closing or latching at time of inspection.
.2537(b) All gates and doors shall be self-closing, self-latching. Operator adjusted gate to self-close, self-latch. |
|
18
|
4
|
Premises: lifeguards present or warning signs posted |
No |
No
|
No |
Pool has placed shelter over pool. Signage not visible upon entry. .2530(c) All pool signage shall be visible upon entrance to the pool and permanently affixed. Operator moved signage inside enclosure and made visible. Corrected. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
Shelter has been placed over pool, emergency phone not visible within enclosure. .2530(f) Emergency phone shall be visible from all areas inside pool enclosure.
.2530(f) Provide signage with location of emergency phone if not visible from all areas inside pool enclosure. Operator added emergency phone location to signage. Corrected. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Pump room is an outside space under deck, built before regulations. Chemical storage has chemicals on pallets that are exposed and visibly reacting to elements. Water on ground in pump room and chemical storage. .2533(d) Pump room floor shall be kept dry and free of standing water.
.2533(d) Pump room floor shall be sloped to drain.
.2534(5) Chemicals shall be stored as to prevent a reaction and permit for easy clean-up.
.2533(a) Pump room shall contain at least all pumps, chemical feeding equipment, and other mechanical and electrical equipment. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
Backwash is underground by grate and no air gap. Original construction. .2513(b) Filter backwash shall be discharged through an air gap. |
|
31
|
2
|
Dressing and sanitary facilities: sewage disposed of in a properly operating sewage system |
No |
No
|
No |
Piping for pool is underground grate from original construction and may not be to code. Unsure if this is sewer or storm, but dispose pool water properly. P{ool is undergoing renovations and this will need to be brought up to Code.
.2513(b) There shall be no direct physical connection between the sewer system and any drain from the swimming pool or circulation system. |