General Comments16) Old fencing against fencing in back, creating horizontals less than 45". Moved back, eliminated horizontals, recommended moving further away from fencing on inside.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Include temperature on records. Operator added temperature. Corrected.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Rusting center line in pool. All metal in pool shall be stainless steel. Pool built with this, prior to 2010.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Replace missing weirs. Operator replaced 2 missing weirs. Corrected.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No .2521(a) Recessed steps or ladders shall be provided at the deep portion of the pool. .2521(a) Steps or ladders shall be provided every 75 ft along the shallow area perimeter. .2521(a) Pools greater than 30 ft wide, shall have a ladder on each side of the deep end. No ladders installed.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2533(d) Pump room floor shall be sloped to drain. .2533(d) Pump room floor shall be kept dry and free of standing water. .2533(a) Pump room shall be weatherproof with a minimum ceiling height of 7 ft. Pump room not enclosed. Built prior to 2010.
27 2 Equipment room: filter backwash discharged through an air gap No No No .2513(b) Filter backwash shall be discharged through an air gap.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No .2626(i) Water in restrooms shall not exceed 110 F.