General Comments22) Emergency phone had static and hard to hear operator. Pool operator changed out phones and it was louder, but still reccomended repairing phone to hear more clearly. Telephone location not posted inside bubble enclosure. If telephone is outside enclosure, location must be listed. Operator added location to 'Pool Rules' sign. Corrected. Onsite visit to pool made and bubble has been installed.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Some leaves and debris on pool floor. Keep clean. Operator came to clean. Corrected.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No 3 weirs missing. Keep functional weirs installed. Operator replaced. Corrected.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Some ladders not installed. One ladder installed, loose and missing stoppers. Keep ladders in good repair and installed.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Gate not self-closing, self-latching at time of inspection. Ensure gates self-close, self latch. Operator tightened and corrected.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Some ladders not installed and leaving holes more than 1'2" offset. Maintain 5' deck clearnace free of trip hazards and clear walking space on indoor pools.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Pump room not enclosed. Pool built prior to 2010. Pump room floor not sloped to drain.
27 2 Equipment room: filter backwash discharged through an air gap No No No Backwash line directly plumbed. Provide air gap at backwash line topit.
30 2 Dressing and sanitary facilities: approved water source, no cross connections No No No Hose bib in chemical storage without backflow prevention device. Provide backflow prevention device on all hose bibs.